Combined distal aortic perfusion and balloon occlusion to facilitate the repair of complex thoracic and thoracoabdominal aortic aneurysms.
Document Type
Article
Publication Title
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
Abstract
We investigated a unique method utilising a Heartport bifurcated arterial cannula and an aortic occlusion balloon to provide both distal perfusion and bloodless, distal arterial exposure during repair of thoracic and thoracoabdominal aortic pathology. Between February 2002 and September 2008, 21 patients underwent thoracic or thoracoabdominal aortic repair with this method. Because of an inability or potential difficulty in achieving distal aortic control secondary to anatomic or technical challenges, a compliant balloon was passed through the accessory arterial channel using fluoroscopic guidance. Adjunctive cerebrospinal drainage was used in all cases. Ballon deployment and satisfactory occlusion was attained in all cases. The overall 30-day mortality rate was 4.75% (1 of 21 patients). Renal failure occurred in one patient (4.75%) and heart failure occurred in two patients (9.5%). Six patients (29%) had pulmonary complications. Transient encephalopathy occurred in two patients (9.5%). Spinal cord neurologic deficit and stroke were avoided in all patients. We recommend the application of this simple method to obtain a bloodless anastomotic field and maintain ongoing distal aortic perfusion in instances where distal control with a clamp is challenging, not feasible or presents the potential for catastrophic intra-operative bleeding.
First Page
1474
Last Page
1476
DOI
10.1016/j.ejcts.2010.01.011
Publication Date
6-1-2010
Recommended Citation
Watson DR, Flesher T. Combined distal aortic perfusion and balloon occlusion to facilitate the repair of complex thoracic and thoracoabdominal aortic aneurysms. Eur J Cardiothorac Surg. 2010 Jun;37(6):1474-6. doi: 10.1016/j.ejcts.2010.01.011. Epub 2010 Feb 26. PMID: 20189408.