Decreasing pacemaker implantation rates with Evolut supra-annular transcatheter aortic valves in a large real-world registry.
Document Type
Article
Publication Title
Cardiovasc Revasc Med
Abstract
BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry.
METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure.
RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus.
CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.
First Page
1
Last Page
9
DOI
10.1016/j.carrev.2024.05.024
Publication Date
12-1-2024
Recommended Citation
Harvey, James E; Puri, Rishi; Grubb, Kendra J; Yakubov, Steven J; Mahoney, Paul D; Gada, Hemal; Coylewright, Megan; Poulin, Marie-France; Chetcuti, Stanley J; Sorajja, Paul; Rovin, Joshua D; Eisenberg, Ruth; and Reardon, Michael J, "Decreasing pacemaker implantation rates with Evolut supra-annular transcatheter aortic valves in a large real-world registry." (2024). Heart and Vascular Articles. 63.